# Detecting Self-Discharge Anomalies

## Understand what self-discharge is, how TWAICE detects abnormal self-discharge in your cells and the logic behind the detection.

**On this page**

- [What is Self-Discharge?](https://support.twaice.com/knowledge/detecting-self-discharge-anomalies#h_8423cbcdae)
- [How TWAICE Detects Self-discharge Anomaly](https://support.twaice.com/knowledge/detecting-self-discharge-anomalies#h_a3994dbd48)
- [Example](https://support.twaice.com/knowledge/detecting-self-discharge-anomalies#h_c88ae8ec05)
- [Detection Logic](https://support.twaice.com/knowledge/detecting-self-discharge-anomalies#h_9fddfbec0c)
- [Turning Detection into Action with TWAICE](https://support.twaice.com/knowledge/detecting-self-discharge-anomalies#h_139564788b)

### **What is Self-Discharge?**

Self-discharge is a natural phenomenon where cells lose charge even when they are not under load. In large-scale battery energy storage systems, however, abnormally high rates of self-discharge are an **early warning signal of deeper issues**. Typical causes include:

- Cell degradation (e.g., lithium plating, electrolyte contamination) or damage
- Manufacturing inconsistencies, external or internal defects
- Environmental conditions such as high humidity

If left unaddressed, abnormal self-discharge can cause both operational and financial damage:

- System imbalance and reduced availability, driving up O&M costs
- Permanent module damage and accelerated degradation
- Lost revenue from downtime and costly replacements

### **How TWAICE Detects Self-discharge Anomaly**

The TWAICE platform continuously monitors cell voltages to identify abnormal divergence. An **anomaly** is flagged in the TWAICE **Safety** section when:

- The **minimum cell voltage in a string is ≥100 mV lower than that of peer strings** in at least 90% of readings over a sustained period.

- **For NMC chemistries**, if this condition lasts less than 5 days, it is marked as "action recommended" (yellow), but if it persists for more than 5 days, it escalates to "action required" (red), as the string may be experiencing ongoing self-discharge and should not simply be recharged without further investigation. The red status remains until the voltage deviation is no longer detected.
- In contrast, **for LFP chemistries**, this issue is less critical and always results in "action recommended" (yellow), regardless of the duration.

### Example

Let’s investigate an example. Here on **Safety** page, a self-charge issue is flagged for **String 6.1.9** due to low cell voltage value compared to other strings in the same parent.

[![](https://support.twaice.com/hubfs/Knowledge%20Base%20Import/Screenshot+2025-10-07+at+16_45_18.png)](https://downloads.intercomcdn.eu/i/o/thagvi83/68422157/de89cfeaf82dafa4dcb295547252/Screenshot+2025-10-07+at+16_45_18.png?expires=1792501200&signature=fd47d50041dc42b5d65c7f029ce5252181c5a1841c0923743dff72d52e15030e&req=1t1rx1r7qTBk2hL085ZhoUEensFt6V82Y%2Fdla3iaD5O33cs0SKmrwThVw2K%2B%0ALCD0P1CBKPcFI45H%0A)

We can view the details in Data Explorer:

[![](https://support.twaice.com/hubfs/Knowledge%20Base%20Import/Screenshot+2025-10-08+at+13_49_27.png)](https://downloads.intercomcdn.eu/i/o/thagvi83/68422342/a9a027588b2ae735ee793599abbf/Screenshot+2025-10-08+at+13_49_27.png?expires=1792501200&signature=8dcafa4b790eba8088336ceaa03e6e13b5fb67c443bc8d137e0ee1f8bfbea126&req=1t1rx1r5qDVk2hL085ZhoRXI7CXMPAsbiQlhyvNJUVR4EjnC64NZ3ldjQpZW%0AZamDzckt%2BKvklzmI%0A)

Most strings remain stable around 3.32 V, while String 6.1.9 (purple) steadily drops to 2.68 V. This persistent voltage gap of over 600 mV clearly indicates abnormal self-discharge and is automatically flagged by the TWAICE platform with recommended actions.

The cell voltage above 2.5 V itself is not a safety critical event yet, but the identification of the component via the self-discharge functionality provides an early detection of faulty components. It is therefore a more sophisticated and precise detection method compared to only using static voltage limits. The method cuts through otherwise noise operational data and highlights the relevant insights.

### **Detection Logic**

**Why we measure voltage**:

- Cell voltage is the most reliable real-time signal for identifying self-discharge.
- It directly reflects the state of charge (SoC), and during standby, voltage drift over time becomes the clearest indicator of abnormal behavior.

**Relation to self-discharge:**

- In a healthy cell, voltage remains stable with only a slow decline.
- In a self-discharging cell, however, voltage drops more quickly due to internal side reactions that consume charge.
- At the string level, this shows up as a consistently lower minimum cell voltage compared to other strings.

**Why compare across strings:**

- Since all strings in a system are exposed to the same conditions, comparing them against each other is a robust way to detect anomalies.
- A persistent difference of **≥100 mV in at least 90% of readings** between one string and its peers reliably signals abnormal self-discharge.

### **Turning Detection into Action with TWAICE**

TWAICE provides a **layer of intelligence on top of BMS data**:

- Detects and flags abnormal self-discharge early
- Highlights **exactly where and when** the anomaly occurs
- Provides **clear recommendations** for preventive actions such as capacity testing or detailed cell-level diagnostics

By intervening before failures escalate, operators can avoid costly replacements, downtime, and safety risks — while extending the useful lifetime of their battery assets.